HXGN-12 Ring Main Unit

Compact 12 kV ring main unit with two ring switches and a fused transformer feeder, rated 630 A and 20 kA / 4 s.

  • Voltage: 12 kV
  • Busbar current: 630 A
  • Short-time withstand: 20 kA / 4 s
  • Protection: IP4X
Share to:

Description

The HXGN-12 ring main unit is the compact medium voltage node of a distribution network: two ring switches and a transformer feeder in one enclosure, with the protection integrated so the unit can be installed at street level, in a compound or inside a substation.

Configuration

  • Ring switches: load break switches for cable-in and cable-out, with earthing switches and interlocks.
  • Transformer feeder: load break switch with fuse, with three-phase tripping when one fuse operates.
  • Extensible: units can be coupled to extend a ring or to add a feeder.
  • Operation: manual as standard, with the option of motorised operation and remote signalling for automation.

Technical data

ParameterTypical value
Rated voltage12 kV
Rated frequency50 Hz
Main busbar rated current630 A
Short-time withstand current20 kA / 4 s
Peak withstand current50 kA
Power frequency withstand (1 min)42 kV
Lightning impulse withstand75 kV
Degree of protectionIP4X (enclosure); sealed gas tank version available
Ambient temperature-25 °C to +40 °C
AltitudeUp to 2000 m
StandardsGB 3906, IEC 62271-200; fuse operation to IEC 60269

Ratings are typical for the standard configuration. The final current, short-circuit and protection ratings are confirmed on the data sheet for the ordered variant.

Where it is used

  • Ring main distribution in residential and commercial areas
  • Transformer protection at the end of a ring
  • Wind and photovoltaic collector networks
  • Industrial plant distribution points
  • Inside YB type compact substations

Ordering information

State the ring configuration (number of ring switches and feeders), the transformer rating to be protected, the fuse or relay protection required, whether motorised operation and remote signalling are needed, and the cable entry arrangement.

FAQ

How many ring switches does the unit have?

The standard configuration has two ring switches and one transformer feeder; units can be coupled to add feeders or extend the ring.

Which protection is used for the transformer feeder?

A load break switch with fuse, with three-phase tripping when one fuse operates. Above about 800 kVA a circuit breaker with relays is normally used instead.

Can the unit be operated remotely?

Yes. Motorised operation and remote signalling are available for distribution automation projects.

Is the unit suitable for outdoor installation?

The enclosure is IP4X and can be installed in a compound or inside a substation enclosure; the sealed gas tank version is used where the environment requires it.